| Element "Straight probe" | Just a simple coaxial excitation. It can be combined with any number of posts (resonant and/or tuning) of different shapes (solid, hollow, mushroom shape, etc...) |
| Element "Mushroom probe" | An excitation with mushroon shape. It can be combined with any number of posts (resonant and/or tuning) of different shapes (solid, hollow, mushroom shape, etc...) |
| Element "Coaxial feed (contact)" | A coaxial excitation contacting the resonant post. The contacted post must be solid. It can be combined with any number of posts (resonant and/or tuning) of different shapes (solid, hollow, mushroom shape, etc...) |
![]() |
![]() |
![]() |
||
| Straight probe |
Mushroom probe |
Coaxial feed (contact) |
![]() |
Extended contact feed- The resonant post can be solid, hollow or mushroom shape. - Cavity can have rounded corners. |
|
![]() |
S-shaped coaxial feed (contact)- The resonant post can be solid, hollow or mushroom shape. - Cavity can have rounded corners. |
|
![]() |
Loop feed- Any number of posts (and any shape) can be inserted in the cavity. - Cavity can have rounded corners. |
|
![]() |
Magnetic feed- Any number of posts (and any shape) can be inserted in the cavity. - Cavity can have rounded corners. |
|
![]() |
Top contact feed- The contacted post has to be solid. - Any number of posts (and any shape) can be additionally inserted in the cavity. - Cavity can have rounded corners. |